{"id":1069,"date":"2015-07-08T09:52:22","date_gmt":"2015-07-08T07:52:22","guid":{"rendered":"http:\/\/lestfrexgn.cluster020.hosting.ovh.net\/?p=1069"},"modified":"2015-06-29T14:04:46","modified_gmt":"2015-06-29T12:04:46","slug":"sccm-212-software-metering-workflow","status":"publish","type":"post","link":"https:\/\/les2t.fr\/fr_fr\/sccm-212-software-metering-workflow\/","title":{"rendered":"SCCM 212 \u2013 Software Metering Workflow"},"content":{"rendered":"<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-83 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg\" alt=\"sccm2012\" width=\"300\" height=\"159\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012.jpg 314w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Pramod Sathyanarayana Kashyap a \u00e9crit un billet sur le Workflow dans Sofware Metering. Je vais ici vous le retranscrire.<\/p>\n<p><!--more--><\/p>\n<ul>\n<li>Cr\u00e9ation d\u2019une r\u00e8gle<\/li>\n<\/ul>\n<p>Pour commencer, nous cr\u00e9ons, tout d&rsquo;abord une r\u00e8gle Software Metering. Dans notre exemple nous allons cr\u00e9er une r\u00e8gle pour le bloc-notes comme indiqu\u00e9 ci-dessous :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1070 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet1-300x227.jpg\" alt=\"SofwareMet1\" width=\"300\" height=\"227\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet1-300x227.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet1.jpg 609w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1071 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet2-300x240.jpg\" alt=\"SofwareMet2\" width=\"300\" height=\"240\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet2-300x240.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet2.jpg 576w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<ul>\n<li>Compilation et cr\u00e9ation de la strat\u00e9gie de suivi<\/li>\n<\/ul>\n<p>Une fois que nous avons activ\u00e9 la r\u00e8gle, les clients re\u00e7oivent la nouvelle politique. Celle-ci est trait\u00e9e lorsque de l\u2019ex\u00e9cution du cycle de contr\u00f4le logiciel :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1072 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet3-300x157.jpg\" alt=\"SofwareMet3\" width=\"300\" height=\"157\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet3-300x157.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet3.jpg 695w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Comme nous pouvons le voir, chaque fois que nous cr\u00e9ons une nouvelle r\u00e8gle de contr\u00f4le de logiciel, la version de la politique change (037effca-e41f-4f28-86a8-ad7481a51deb). Dans notre exemple, apr\u00e8s avoir cr\u00e9\u00e9 une r\u00e8gle de 3rd pour le bloc-notes, la version change \u00e0 3,00. Voici l&rsquo;extrait du log PolicyAgentProvider.log :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1073 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet4-300x14.jpg\" alt=\"SofwareMet4\" width=\"300\" height=\"14\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet4-300x14.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet4.jpg 627w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Voici ce que nous voyons au cours du processus dans PolicyAgent.log :<\/p>\n<p><em><span style=\"color: #ff0000;\">Requesting Machine policy assignments PolicyAgent_RequestAssignments 9\/24\/2014 3:49:58 AM 4772 (0x12A4)<\/span><\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Total 1 PolicyAssignment(s) found. PolicyAgent_ReplyAssignments 9\/24\/2014 3:49:59 AM 3564 (0x0DEC)<\/span><\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Policy Body :&lt;PolicyAssignment PolicyAssignmentID=\u00a0\u00bb{7da6c723-2d5d-4a50-8d30-53e714a2c984}\u00a0\u00bb&gt;<\/span><\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">&lt;Policy PolicyID=\u00a0\u00bb{037effca-e41f-4f28-86a8-ad7481a51deb}\u00a0\u00bb PolicyVersion=\u00a0\u00bb3.00&Prime; PolicyType=\u00a0\u00bbMachine\u00a0\u00bb&gt;<\/span><\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Compiling policy &lsquo;{037effca-e41f-4f28-86a8-ad7481a51deb}&rsquo; version &lsquo;3.00&rsquo; hash<\/span><\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Initializing download of policy &lsquo;CCM_Policy_Policy5.PolicyID=\u00a0\u00bb{037effca-e41f-4f28-86a8-ad7481a51deb}\u00a0\u00bb,PolicySource=\u00a0\u00bbSMS:PR1&Prime;,PolicyVersion=\u00a0\u00bb3.00&Prime;&lsquo; from &lsquo;http:\/\/SEC.contoso.com\/SMS_MP\/.sms_pol?{037effca-e41f-4f28-86a8-ad7481a51deb}.3_00&rsquo;<\/span> PolicyAgent_ReplyAssignments 9\/24\/2014 3:50:00 AM 3564 (0x0DEC)<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Revoking policy &lsquo;{037effca-e41f-4f28-86a8-ad7481a51deb}&rsquo; version &lsquo;2.00&rsquo;<\/span> PolicyAgent_PolicyDownload 9\/24\/2014 3:50:02 AM 3792 (0x0ED0)<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Deleting policy &lsquo;{037effca-e41f-4f28-86a8-ad7481a51deb}&rsquo; version &lsquo;2.00&rsquo;<\/span> PolicyAgent_PolicyDownload 9\/24\/2014 3:50:03 AM 3792 (0x0ED0)<\/em><\/p>\n<p><em>Deleting policy file C:\\Windows\\CCM\\Staging\\{A56CBE49-456C-4575-ABCE-8B7C68309A71}.tmp PolicyAgent_PolicyDownload 9\/24\/2014 3:50:03 AM 3792 (0x0ED0)<\/em><\/p>\n<p><em>Recieved notification of policy download and evaluation complete for correlation guid {8CC44587-E82E-47AF-8449-BA069FF1683C} PolicyAgent_RequestAssignments 9\/24\/2014 3:50:12 AM 4772 (0x12A4)<\/em><\/p>\n<p><em>Synchronous policy assignment request with correlation guid {8CC44587-E82E-47AF-8449-BA069FF1683C} for Machine C1 completed with status 0 PolicyAgent_RequestAssignments 9\/24\/2014 3:50:12 AM 4772 (0x12A4)<\/em><\/p>\n<p>Ensuite, nous pouvons voir ces \u00e9v\u00e9nements dans le mtrmgr.log :<\/p>\n<p><em><span style=\"color: #ff0000;\">Process ID 3772 is for process C:\\Users\\administrator\\Desktop\\CMTrace.exe<\/span> mtrmgr 8\/29\/2014 2:33:12 AM 2180 (0x0884)\u00a0<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Found match against RuleID PR100001<\/span> mtrmgr 8\/29\/2014 2:33:12 AM 4956 (0x135C)<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Tracked usage for process 3772<\/span> mtrmgr 8\/29\/2014 2:33:12 AM 4956 (0x135C)<\/em><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>Recherchez les m\u00eames entr\u00e9es dans WMI<\/li>\n<\/ul>\n<p>Ces informations sont ensuite \u00e9crites dans l&rsquo;infrastructure WMI \u00e0 l&rsquo;aide de Softaware Metering Storage Manager dans root\\ccm\\SoftwareMeteringAgent. Ici, nous trouvons les cat\u00e9gories ci-dessous.<\/p>\n<ul>\n<li>CCM_MeteredFileInfo \u2013D\u00e9tails des *.exe qui sont actuellement mesur\u00e9s.<\/li>\n<li>CCM_MeteredProductInfo \u2013 Renseignements semblables que ci-dessus.<\/li>\n<li>CCM_RecentlyUsedApps \u2013 Noms des fichiers qui ont \u00e9t\u00e9 ex\u00e9cut\u00e9s r\u00e9cemment.<\/li>\n<li>CCM_HistoricalMeteredData \u2013 enregistre les donn\u00e9es d\u2019historiques.<\/li>\n<\/ul>\n<p>Ci-dessous les Screenshots de celles-ci :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1074 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet5-300x258.jpg\" alt=\"SofwareMet5\" width=\"300\" height=\"258\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet5-300x258.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet5.jpg 623w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1075 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet6-300x267.jpg\" alt=\"SofwareMet6\" width=\"300\" height=\"267\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet6-300x267.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet6.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>C&rsquo;est ensuite trait\u00e9 par le Software Metering Report Generator qui va chercher les d\u00e9tails dans Storage Manager et WMI. Au cours de ce processus, il transforme les fichiers au format XML, et les ins\u00e8res dans un *. MUV.<\/p>\n<p>Apr\u00e8s l&rsquo;envoi du rapport (tel que montr\u00e9 ci-dessous), il envoie une demande de purge des donn\u00e9es WMI qui ont d\u00e9j\u00e0 \u00e9t\u00e9 envoy\u00e9e.<\/p>\n<p><em>CSWMtrReportEndpoint::HandleMessage- Report Endpoint invoked. SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)\u00a0<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Generating report for usage data<\/span> SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>About to generate report header SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">Successfully generated report header<\/span> SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>About to generate report body SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>Successfully generated report body SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>About to generate report header SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>Successfully generated report header SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>MRU Refresh is 15 minutes. SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em>MRU Age limit is 90 days. SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p><em><span style=\"color: #ff0000;\">CSWMtrReportEndpoint- Message ID of sent message: {D9ACA606-A6E6-4CE8-82E4-68E6DA86801B}<\/span> SWMTRReportGen 8\/29\/2014 2:32:54 AM 2268 (0x08DC)<\/em><\/p>\n<p>&nbsp;<\/p>\n<p>Ces donn\u00e9es sont ensuite envoy\u00e9es vers le MP_Relay EndPoint puis vers swmproc.box pour traitement. Apr\u00e8s cela, nous serons en mesure de voir tous les d\u00e9tails.<\/p>\n<ul>\n<li>Flux de travail de Software Metering Collection et Reporting<\/li>\n<\/ul>\n<p>Voici le flux dans un environnement o\u00f9 nous avons un CAS, un primaire et un serveur secondaire. Tout d&rsquo;abord, les donn\u00e9es sont stock\u00e9es dans le dossier \u00ab C:\\Windows\\CCM\\Metering \u00bb :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet7.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1076 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet7-300x95.jpg\" alt=\"SofwareMet7\" width=\"300\" height=\"95\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet7-300x95.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet7.jpg 486w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Puis quand le cycle de Software Metering d\u00e9marre, il envoie un rapport et celui-ci est re\u00e7u par le MP_Relay Endpoint sur le secondaire :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet8.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1077 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet8-300x24.jpg\" alt=\"SofwareMet8\" width=\"300\" height=\"24\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet8-300x24.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet8.jpg 628w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Ensuite, il est d\u00e9plac\u00e9 vers swmproc.box sur le secondaire pour traitement :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet9.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1078 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet9-300x94.jpg\" alt=\"SofwareMet9\" width=\"300\" height=\"94\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet9-300x94.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet9.jpg 623w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Maintenant, Software Metering Processor du secondaire additionne les fichiers utilisation et le transfert au primaire en utilisant DRS :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet10.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1079 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet10-300x60.png\" alt=\"SofwareMet10\" width=\"300\" height=\"60\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet10-300x60.png 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet10.png 942w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Nous pouvons voir l&rsquo;exp\u00e9diteur qui envoie les fichiers vers le serveur Primaire :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet11.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1080 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet11-300x151.png\" alt=\"SofwareMet11\" width=\"300\" height=\"151\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet11-300x151.png 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet11.png 941w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Dans le primaire, nous pouvons voir les m\u00eames fichiers \u00e0 leur r\u00e9ception par le Despooler :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet12.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1081 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet12-300x92.png\" alt=\"SofwareMet12\" width=\"300\" height=\"92\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet12-300x92.png 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet12.png 937w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Apr\u00e8s l&rsquo;ach\u00e8vement de la r\u00e9plication, le fichier *. MUV est d\u00e9plac\u00e9 vers swmprox.box sur le primaire :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet13.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1082 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet13-300x4.png\" alt=\"SofwareMet13\" width=\"300\" height=\"4\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet13-300x4.png 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet13.png 939w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Il est ensuite trait\u00e9 par le Software Metering processor sur le primaire :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet14.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1083 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet14-300x51.png\" alt=\"SofwareMet14\" width=\"300\" height=\"51\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet14-300x51.png 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet14.png 941w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Le d\u00e9placement de fichier peut \u00eatre vu ici dans les dossiers sur le primaire :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet15.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1084 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet15-300x138.jpg\" alt=\"SofwareMet15\" width=\"300\" height=\"138\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet15-300x138.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet15.jpg 547w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Une fois fini et les t\u00e2ches de maintenance ex\u00e9cut\u00e9es, les donn\u00e9es de mesure seront enfin disponibles pour l&rsquo;affichage sur la console :<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet16.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1085 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet16-268x300.jpg\" alt=\"SofwareMet16\" width=\"268\" height=\"300\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet16-268x300.jpg 268w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet16.jpg 517w\" sizes=\"(max-width: 268px) 100vw, 268px\" \/><\/a><\/p>\n<p><strong>NOTE<\/strong> : Si vous voulez acc\u00e9l\u00e9rer ce processus, vous pouvez d\u00e9clencher manuellement, ce qui peut \u00eatre utile si vous \u00eates\u00a0 en cour de r\u00e9solution d\u2019un probl\u00e8me. Pour cela, t\u00e9l\u00e9chargez <a href=\"http:\/\/www.microsoft.com\/en-us\/download\/details.aspx?id=29265\" target=\"_blank\">Configuration Manager 2012 Toolkit <\/a>\u00a0et installez-le. Une fois install\u00e9, regardez dans le dossier Server Tools l\u2019executable runmetersumm.exe. Ce fichier peut \u00eatre ex\u00e9cut\u00e9 sur l&rsquo;instance SQL h\u00e9bergeant la base de donn\u00e9es de Configuration Manager pour d\u00e9clencher le processus de synth\u00e8se. La commande \u00e0 ex\u00e9cuter est runmetersumm.exe DBName.<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet17.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1086 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet17-300x170.jpg\" alt=\"SofwareMet17\" width=\"300\" height=\"170\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet17-300x170.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet17.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet18.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-medium wp-image-1087 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet18-300x118.jpg\" alt=\"SofwareMet18\" width=\"300\" height=\"118\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet18-300x118.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/06\/SofwareMet18.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Juste pour r\u00e9f\u00e9rence, voici un exemple de fichier MUX captur\u00e9 pendant le flux:<\/p>\n<p><span style=\"color: #3366ff;\">&lt;?xml version=&rsquo;1.0&prime; encoding=&rsquo;UTF-16&prime;?&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Report&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ReportHeader&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Identification&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Machine&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ClientInstalled&gt;1&lt;\/ClientInstalled&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ClientType&gt;1&lt;\/ClientType&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ClientID&gt;GUID:E58CDD17-B377-49A0-9584-80224C12C827&lt;\/ClientID&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ClientVersion&gt;5.00.7958.1000&lt;\/ClientVersion&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;NetBIOSName&gt;C1&lt;\/NetBIOSName&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;CodePage&gt;437&lt;\/CodePage&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;SystemDefaultLCID&gt;1033&lt;\/SystemDefaultLCID&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/Machine&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/Identification&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ReportDetails&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ReportContent&gt;Software\\x0020Metering\\x0020Data&lt;\/ReportContent&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ReportType&gt;Full&lt;\/ReportType&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Date&gt;20141001043107.864000-420&lt;\/Date&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Version&gt;1.0&lt;\/Version&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;Format&gt;1.0&lt;\/Format&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/ReportDetails&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/ReportHeader&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ReportBody&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;ProductInfo CompanyName=\u00a0\u00bbMicrosoft Corporation\u00a0\u00bb ProductName=\u00a0\u00bbSystem Center 2012 Configuration Manager\u00a0\u00bb ProductVersion=\u00a0\u00bb5.00.7804.1000&Prime; ProductLanguage=\u00a0\u00bb0&Prime;&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;SoftwareFileInfo FileDescription=\u00a0\u00bbConfiguration Manager Trace Log Tool\u00a0\u00bb FileVersion=\u00a0\u00bb5.00.7804.1000 (hermbld.121121-2357)\u00a0\u00bb FileName=\u00a0\u00bbCMTrace.exe\u00a0\u00bb FileSize=\u00a0\u00bb678480&Prime;&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;HistoricalMeterData MeteredDataID=\u00a0\u00bbF32846B9-7846-44D4-9162-4F54D2D0A54F\u00a0\u00bb UserName=\u00a0\u00bbCONTOSO\\Administrator\u00a0\u00bb StartTime=\u00a0\u00bb20141001042204.000000-420&Prime; EndTime=\u00a0\u00bb20141001043107.911000-420&Prime; Status=\u00a0\u00bb1&Prime;&gt;&lt;\/HistoricalMeterData&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;HistoricalMeterData MeteredDataID=\u00a0\u00bbC0C6FE62-3793-48D2-998D-BA036F2F345C\u00a0\u00bb UserName=\u00a0\u00bbCONTOSO\\Administrator\u00a0\u00bb StartTime=\u00a0\u00bb20141001040049.000000-420&Prime; EndTime=\u00a0\u00bb20141001043107.911000-420&Prime; Status=\u00a0\u00bb1&Prime;&gt;&lt;\/HistoricalMeterData&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/SoftwareFileInfo&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/ProductInfo&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/ReportBody&gt;<\/span><br \/>\n<span style=\"color: #3366ff;\">&lt;\/Report&gt;<\/span><\/p>\n<p>Cela montre les donn\u00e9es envoy\u00e9es par un client apr\u00e8s avoir ex\u00e9cut\u00e9 le cycle Software Metering.<\/p>\n<ul>\n<li>Le billet original : <a href=\"http:\/\/blogs.technet.com\/b\/configurationmgr\/archive\/2015\/05\/27\/taking-a-look-at-the-software-metering-workflow-in-system-center-2012-configuration-manager.aspx\" target=\"_blank\">ICI<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Pramod Sathyanarayana Kashyap a \u00e9crit un billet sur le Workflow dans Sofware Metering. Je vais ici vous le retranscrire.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[7],"tags":[36,164,141,172,22,48],"class_list":["post-1069","post","type-post","status-publish","format-standard","hentry","category-sccm-2012","tag-microsoft","tag-sccm-2012","tag-software-metering","tag-system-center","tag-system-center-configuration-manager","tag-windows"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SCCM 212 \u2013 Software Metering Workflow - Les2T<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/les2t.fr\/fr_fr\/sccm-212-software-metering-workflow\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SCCM 212 \u2013 Software Metering Workflow - Les2T\" \/>\n<meta property=\"og:description\" content=\"Pramod Sathyanarayana Kashyap a \u00e9crit un billet sur le Workflow dans Sofware Metering. Je vais ici vous le retranscrire.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/les2t.fr\/fr_fr\/sccm-212-software-metering-workflow\/\" \/>\n<meta property=\"og:site_name\" content=\"Les2T\" \/>\n<meta property=\"article:published_time\" content=\"2015-07-08T07:52:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg\" \/>\n<meta name=\"author\" content=\"TRARBACH Jean-Yves\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"TRARBACH Jean-Yves\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/\",\"url\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/\",\"name\":\"SCCM 212 \u2013 Software Metering Workflow - Les2T\",\"isPartOf\":{\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg\",\"datePublished\":\"2015-07-08T07:52:22+00:00\",\"author\":{\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e\"},\"breadcrumb\":{\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage\",\"url\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg\",\"contentUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/les2t.fr\/fr_fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SCCM 212 \u2013 Software Metering Workflow\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#website\",\"url\":\"https:\/\/les2t.fr\/fr_fr\/\",\"name\":\"Les2T\",\"description\":\"| BLOG  IT |\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/les2t.fr\/fr_fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e\",\"name\":\"TRARBACH Jean-Yves\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg\",\"contentUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg\",\"caption\":\"TRARBACH Jean-Yves\"},\"description\":\"Head Of Modern Workplace Metsys MVP Windows &amp; devices For IT\",\"sameAs\":[\"https:\/\/les2t.fr\/jean-yves-trarbach\/\"],\"url\":\"https:\/\/les2t.fr\/fr_fr\/author\/kounac\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SCCM 212 \u2013 Software Metering Workflow - Les2T","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/les2t.fr\/fr_fr\/sccm-212-software-metering-workflow\/","og_locale":"fr_FR","og_type":"article","og_title":"SCCM 212 \u2013 Software Metering Workflow - Les2T","og_description":"Pramod Sathyanarayana Kashyap a \u00e9crit un billet sur le Workflow dans Sofware Metering. Je vais ici vous le retranscrire.","og_url":"https:\/\/les2t.fr\/fr_fr\/sccm-212-software-metering-workflow\/","og_site_name":"Les2T","article_published_time":"2015-07-08T07:52:22+00:00","og_image":[{"url":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg","type":"","width":"","height":""}],"author":"TRARBACH Jean-Yves","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"TRARBACH Jean-Yves","Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/","url":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/","name":"SCCM 212 \u2013 Software Metering Workflow - Les2T","isPartOf":{"@id":"https:\/\/les2t.fr\/fr_fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage"},"image":{"@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage"},"thumbnailUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg","datePublished":"2015-07-08T07:52:22+00:00","author":{"@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e"},"breadcrumb":{"@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#primaryimage","url":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg","contentUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2012-300x159.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/les2t.fr\/sccm-212-software-metering-workflow\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/les2t.fr\/fr_fr\/"},{"@type":"ListItem","position":2,"name":"SCCM 212 \u2013 Software Metering Workflow"}]},{"@type":"WebSite","@id":"https:\/\/les2t.fr\/fr_fr\/#website","url":"https:\/\/les2t.fr\/fr_fr\/","name":"Les2T","description":"| BLOG  IT |","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/les2t.fr\/fr_fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e","name":"TRARBACH Jean-Yves","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/image\/","url":"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg","contentUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg","caption":"TRARBACH Jean-Yves"},"description":"Head Of Modern Workplace Metsys MVP Windows &amp; devices For IT","sameAs":["https:\/\/les2t.fr\/jean-yves-trarbach\/"],"url":"https:\/\/les2t.fr\/fr_fr\/author\/kounac\/"}]}},"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/posts\/1069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/comments?post=1069"}],"version-history":[{"count":0,"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/posts\/1069\/revisions"}],"wp:attachment":[{"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/media?parent=1069"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/categories?post=1069"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/les2t.fr\/fr_fr\/wp-json\/wp\/v2\/tags?post=1069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}