{"id":720,"date":"2015-03-09T10:11:36","date_gmt":"2015-03-09T09:11:36","guid":{"rendered":"http:\/\/lestfrexgn.cluster020.hosting.ovh.net\/?p=720"},"modified":"2015-03-09T10:11:36","modified_gmt":"2015-03-09T09:11:36","slug":"sccm-2007-fusionner-les-enregistrements-obsoletes","status":"publish","type":"post","link":"https:\/\/les2t.fr\/en_us\/sccm-2007-fusionner-les-enregistrements-obsoletes\/","title":{"rendered":"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes"},"content":{"rendered":"<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-94 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg\" alt=\"sccm2007\" width=\"300\" height=\"69\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg 300w, https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007.jpg 499w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Lors de la r\u00e9installation d&rsquo;un ordinateur qui est d\u00e9j\u00e0 pr\u00e9sent dans Configuration Manager 2007, vous vous retrouvez r\u00e9guli\u00e8rement avec des enregistrements en double, un client actif et l\u2019autre obsol\u00e8te.<\/p>\n<p><!--more--><br \/>\nVous pouvez bien entendu activer le nettoyage int\u00e9gr\u00e9 \u00e0 SCCM en suppriment ces enregistrement r\u00e9guli\u00e8rement, mais vous perdrez l\u2019historique mais aussi l\u2019affectation \u00e0 des regroupements par adh\u00e9sion directe.<br \/>\nPour contourner le probl\u00e8me, il existe une solution reli\u00e9 sur le site CCMEXEC.com permettant de fusionner les enregistrements.<br \/>\nPour cela il vous faudra disposer d\u2019un script vbs :<\/p>\n<p>[pastacode lang=\u00a0\u00bbjavascript\u00a0\u00bb message=\u00a0\u00bb\u00a0\u00bb highlight=\u00a0\u00bb\u00a0\u00bb provider=\u00a0\u00bbmanual\u00a0\u00bb]<\/p>\n<pre><code>Dim swbemLocator\r\nDim swbemServices \r\n\r\nMain() \r\n\r\nSub Main()\r\nDim oProviderLocation\r\nDim oLocation\r\nDim oReg\r\nDim oPendingRegs\r\n    Set swbemLocator = CreateObject(&#34;WbemScripting.SWbemLocator&#34;)\r\n    swbemLocator.Security_.AuthenticationLevel = 6 &#039;Packet Privacy.\r\n    Set swbemServices = swbemLocator.ConnectServer(&#34;.&#34;, &#34;root\\SMS&#34;)\r\n    Set oProviderLocation = swbemServices.InstancesOf(&#34;SMS_ProviderLocation&#34;)\r\n    For Each oLocation In oProviderLocation\r\n        If oLocation.ProviderForLocalSite = True Then\r\n            Set swbemServices = swbemLocator.ConnectServer(oLocation.Machine, &#34;root\\sms\\site_&#34; + oLocation.SiteCode)\r\n        End If        \r\n    Next \r\n\r\n    Set oPendingRegs = swbemServices.ExecQuery(&#34;SELECT * FROM SMS_PendingRegistrationRecord&#34;)\r\n    For Each oReg In oPendingRegs\r\n        Resolve 1, oReg.SMSID\r\n    Next \r\n\r\nEnd Sub \r\n\r\nSub Resolve(action, SMSID)\r\nDim InParams\r\n    Set InParams = swbemServices.Get(&#34;SMS_PendingRegistrationRecord&#34;).Methods_(&#34;ResolvePendingRegistrationRecord&#34;).InParameters.SpawnInstance_\r\n    InParams.Action = action\r\n    InParams.SMSID = SMSID \r\n\r\n    swbemServices.ExecMethod &#34;SMS_PendingRegistrationRecord&#34;,&#34;ResolvePendingRegistrationRecord&#34;, InParams\r\nEnd Sub<\/code><\/pre>\n<p>[\/pastacode]<\/p>\n<p>Ici on l\u2019appellera merge.vbs et il vous faudra le copier dans un r\u00e9pertoire de votre serveur SCCM. Exemple : e:\\sccmtools<br \/>\nPour l\u2019ex\u00e9cuter, nous nous servirons des filtres d\u2019\u00e9tat de SCCM.<br \/>\nMais avant nous devons modifier les param\u00e8tres du site en cochant sous l\u2019onglet Avanced l\u2019option \u00ab Manually resolve conflicting records \u00bb<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-723 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords2-255x300.png\" alt=\"MergeRecords2\" width=\"255\" height=\"300\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords2-255x300.png 255w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords2.png 506w\" sizes=\"(max-width: 255px) 100vw, 255px\" \/><\/a><\/p>\n<p>Cr\u00e9ons ensuite une nouvelle r\u00e8gle de filtre d\u2019\u00e9tat avec somme composant SMS_DISCOVERY_DATA_MANAGER et comme ID du Message : 2642<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-722 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords-271x300.png\" alt=\"MergeRecords\" width=\"271\" height=\"300\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords-271x300.png 271w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords.png 404w\" sizes=\"(max-width: 271px) 100vw, 271px\" \/><\/a><br \/>\nIndiquons ensuite le programme qui doit \u00eatre ex\u00e9cut\u00e9 lorsque cette ID est d\u00e9couvert.<br \/>\nSi vous avez des probl\u00e8mes d\u2019ex\u00e9cution utilisez le chemin complet (c:\\windows\\syswow64\\cscript.exe e:\\sccmtools\\merge.vbs)<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords3.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-724 aligncenter\" src=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords3-272x300.png\" alt=\"MergeRecords3\" width=\"272\" height=\"300\" srcset=\"https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords3-272x300.png 272w, https:\/\/les2t.fr\/wp-content\/uploads\/2015\/03\/MergeRecords3.png 403w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><\/a><br \/>\nEt voil\u00e0, vous n\u2019aurez plus d\u2019enregistrement obsol\u00e8te ni de probl\u00e8me lors d\u2019adh\u00e9sion direct avant un formatage.<br \/>\nLien vers l\u2019article original : <a href=\"http:\/\/ccmexec.com\/2011\/03\/merging-obsolete-records-in-configuration-manager-2007\/\" target=\"_blank\">ICI<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Lors de la r\u00e9installation d&rsquo;un ordinateur qui est d\u00e9j\u00e0 pr\u00e9sent dans Configuration Manager 2007, vous vous retrouvez r\u00e9guli\u00e8rement avec des enregistrements en double, un client actif et l\u2019autre obsol\u00e8te.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[8],"tags":[15,165,22],"class_list":["post-720","post","type-post","status-publish","format-standard","hentry","category-sccm-2007","tag-configmgr-2007","tag-sccm-2007","tag-system-center-configuration-manager"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/les2t.fr\/en_us\/sccm-2007-fusionner-les-enregistrements-obsoletes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T\" \/>\n<meta property=\"og:description\" content=\"Lors de la r\u00e9installation d&rsquo;un ordinateur qui est d\u00e9j\u00e0 pr\u00e9sent dans Configuration Manager 2007, vous vous retrouvez r\u00e9guli\u00e8rement avec des enregistrements en double, un client actif et l\u2019autre obsol\u00e8te.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/les2t.fr\/en_us\/sccm-2007-fusionner-les-enregistrements-obsoletes\/\" \/>\n<meta property=\"og:site_name\" content=\"Les2T\" \/>\n<meta property=\"article:published_time\" content=\"2015-03-09T09:11:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg\" \/>\n<meta name=\"author\" content=\"TRARBACH Jean-Yves\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"TRARBACH Jean-Yves\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/\",\"url\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/\",\"name\":\"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T\",\"isPartOf\":{\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg\",\"datePublished\":\"2015-03-09T09:11:36+00:00\",\"author\":{\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e\"},\"breadcrumb\":{\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage\",\"url\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg\",\"contentUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/les2t.fr\/fr_fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#website\",\"url\":\"https:\/\/les2t.fr\/fr_fr\/\",\"name\":\"Les2T\",\"description\":\"| BLOG  IT |\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/les2t.fr\/fr_fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e\",\"name\":\"TRARBACH Jean-Yves\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg\",\"contentUrl\":\"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg\",\"caption\":\"TRARBACH Jean-Yves\"},\"description\":\"Head Of Modern Workplace Metsys MVP Windows &amp; devices For IT\",\"sameAs\":[\"https:\/\/les2t.fr\/jean-yves-trarbach\/\"],\"url\":\"https:\/\/les2t.fr\/en_us\/author\/kounac\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/les2t.fr\/en_us\/sccm-2007-fusionner-les-enregistrements-obsoletes\/","og_locale":"en_US","og_type":"article","og_title":"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T","og_description":"Lors de la r\u00e9installation d&rsquo;un ordinateur qui est d\u00e9j\u00e0 pr\u00e9sent dans Configuration Manager 2007, vous vous retrouvez r\u00e9guli\u00e8rement avec des enregistrements en double, un client actif et l\u2019autre obsol\u00e8te.","og_url":"https:\/\/les2t.fr\/en_us\/sccm-2007-fusionner-les-enregistrements-obsoletes\/","og_site_name":"Les2T","article_published_time":"2015-03-09T09:11:36+00:00","og_image":[{"url":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg","type":"","width":"","height":""}],"author":"TRARBACH Jean-Yves","twitter_card":"summary_large_image","twitter_misc":{"Written by":"TRARBACH Jean-Yves","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/","url":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/","name":"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes - Les2T","isPartOf":{"@id":"https:\/\/les2t.fr\/fr_fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage"},"image":{"@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage"},"thumbnailUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg","datePublished":"2015-03-09T09:11:36+00:00","author":{"@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e"},"breadcrumb":{"@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#primaryimage","url":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg","contentUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2014\/09\/sccm2007-300x69.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/les2t.fr\/sccm-2007-fusionner-les-enregistrements-obsoletes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/les2t.fr\/fr_fr\/"},{"@type":"ListItem","position":2,"name":"SCCM 2007 \u2013 Fusionner les enregistrements obsol\u00e8tes"}]},{"@type":"WebSite","@id":"https:\/\/les2t.fr\/fr_fr\/#website","url":"https:\/\/les2t.fr\/fr_fr\/","name":"Les2T","description":"| BLOG  IT |","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/les2t.fr\/fr_fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/d96bb4f512f9aeb12dc923def245768e","name":"TRARBACH Jean-Yves","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/les2t.fr\/fr_fr\/#\/schema\/person\/image\/","url":"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg","contentUrl":"https:\/\/les2t.fr\/wp-content\/uploads\/2023\/02\/JeanYvestrarbach-96x96.jpg","caption":"TRARBACH Jean-Yves"},"description":"Head Of Modern Workplace Metsys MVP Windows &amp; devices For IT","sameAs":["https:\/\/les2t.fr\/jean-yves-trarbach\/"],"url":"https:\/\/les2t.fr\/en_us\/author\/kounac\/"}]}},"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/posts\/720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/comments?post=720"}],"version-history":[{"count":0,"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/posts\/720\/revisions"}],"wp:attachment":[{"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/media?parent=720"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/categories?post=720"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/les2t.fr\/en_us\/wp-json\/wp\/v2\/tags?post=720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}